Milnor 30022V6J Installation Manual

Browse online or download Installation Manual for Washing machines Milnor 30022V6J. Milnor 30022V6J Installation manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 85
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Published Manual Number: MTCJUR03
• Specified Date: 20070828
• As-of Date: 20070828
• Access Date: 20070828
• Custom: n/a
• Applicability: CJH CJV MXU
• Language Code: ENG01, Purpose: publication, Format: 1colA
Technical Reference—
Using the E-P Plus
®
Control on H_J, V_J,
X_J, and MWR_ Models
PELLERIN MILNOR CORPORATION POST OFFICE BOX 400, KENNER, LOUISIANA 70063 - 0400, U.S.A.
Page view 0
1 2 3 4 5 6 ... 84 85

Summary of Contents

Page 1 - X_J, and MWR_ Models

Published Manual Number: MTCJUR03 • Specified Date: 20070828 • As-of Date: 20070828 • Access Date: 20070828 • Custom: n/a • Applicability: CJH

Page 2 - products by model number:

Chapter 1. Commissioning PELLERIN MILNOR CORPORATION Chapter 1 Commissioning BIRHUK01 (Published) Book specs- Dates: 20070828 / 20070828

Page 3 - Preface

Chapter 1. Commissioning PELLERIN MILNOR CORPORATION Table 3: Data Use and Alteration Data Type How Data can be Used and Altered Configurati

Page 4 - — End of BIRHUK02 —

Chapter 1. Commissioning PELLERIN MILNOR CORPORATION BIWUUI01 (Published) Book specs- Dates: 20070828 / 20070828 / 20070828 Lang: ENG01 A

Page 5 - Table of Contents

Chapter 1. Commissioning PELLERIN MILNOR CORPORATION Figure 2: Proper Routing of Chemical Tubing Note 1: As shown in Figure 2, all tanks, pump

Page 6

Chapter 1. Commissioning PELLERIN MILNOR CORPORATION Figure 3: Rear-mounted Water and Liquid Supply Injector Figure Legend .

Page 7

Chapter 1. Commissioning PELLERIN MILNOR CORPORATION • Lock off and tag out power at the external disconnect switches for the washer-extractor an

Page 8

Chapter 1. Commissioning PELLERIN MILNOR CORPORATION 1.4.1.1. Chemical Injection Output Signals—Five discrete signals (for chemicals 1 through

Page 9 - Storage Device

Chapter 1. Commissioning PELLERIN MILNOR CORPORATION Table 4: Chemical Injection Signals for H_J, X_J, and 30-inch V_J Models Signal Component

Page 10 - Commissioning

Chapter 2. Programming PELLERIN MILNOR CORPORATION Chapter 2 Programming BICJHC01 (Published) Book specs- Dates: 20070828 / 20070828 / 2

Page 11 - 1.2. Determining Load Size

Chapter 2. Programming PELLERIN MILNOR CORPORATION Figure 4: Typical Control Panels Control Panel for X_J Models Legend 1. Start button 2. Run

Page 12 - Internal Damage

Applicable Milnor® products by model number: 30022H7J 30022H8J 30015T5J 30015V7J 30022T5J 30022V6J 30022X8J 36021V5J 36026V5J 36026V7J 360

Page 13 - External Damage

Chapter 2. Programming PELLERIN MILNOR CORPORATION while the Scroll Up button is pressed, the machine displays the status of the microprocessor

Page 14 - Chapter 1. Commissioning

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.1.2. Control Functions During Manual Operation Manual operation is used primarily for troub

Page 15 - Supplement 2

Chapter 2. Programming PELLERIN MILNOR CORPORATION 8. The Signal Cancel button is not used in programming. 9. The Operator Signal light is not u

Page 16

Chapter 2. Programming PELLERIN MILNOR CORPORATION Figure 5: Location of DIP Switches Processor Board Legend A. DIP switch B. Board identific

Page 17 - Chapter 1. Commissioning

Chapter 2. Programming PELLERIN MILNOR CORPORATION • Option 4: DATA TRANSFER Each of these options is described in detail in this document. For

Page 18 - Programming

Chapter 2. Programming PELLERIN MILNOR CORPORATION Supplement 3 What are Formulas, Steps, and Decisions? In this manual a wash formula is

Page 19 - Chapter 2. Programming

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.3.2. Moving Forward and Backward through Steps and Decisions—Each step has two displays:

Page 20

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.3.3. Create a New Formula—Creating a new formula with the E-P Plus® controller entails add

Page 21 - Chapter 2. Programming

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.3.5. Change an Existing Formula 2.3.3.5.1. How to Insert or Delete a Step in an Existi

Page 22

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation 03 TMMQFFFHC LSCWSS* 01 This is a typical Typ

Page 23 - Controller

Preface PELLERIN MILNOR CORPORATION Preface BIRHUK02 (Published) Book specs- Dates: 20070828 / 20070828 / 20070828 Lang: ENG01 Applic: CJH

Page 24 - How to Avoid Data Loss

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation CAUTION 13 : Avoid damage to extract motor—For H_J mode

Page 25 - Supplement 3

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation 03 TMMQFFFHC LSCWSS* 01 x Control of cold water

Page 26

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2. The machine must be configured for temperature control (Temp Control = YES) as described

Page 27

Chapter 2. Programming PELLERIN MILNOR CORPORATION 5. When the one-minute step time expires, the cooldown valve closes and the drain opens. The d

Page 28

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.3.5.5. How to Select the Steam Code Display or Action Explanation 03 TMMQFFFHC

Page 29

Chapter 2. Programming PELLERIN MILNOR CORPORATION Table 6: Summary of E-P Plus Steam Code Choices Steam Code Steaming can begin at the earlie

Page 30

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.3.5.6. Injecting Chemicals Display or Action Explanation 03 TMMQFFFHC LSCWSS* 0

Page 31 - Supplement 4

Chapter 2. Programming PELLERIN MILNOR CORPORATION Table 7: Codes for Inject Times of 100 Seconds and Longer Alphabetic Code Value Alphabeti

Page 32

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.3.5.7. Concluding Decisions Display or Action Explanation 03 SPD D E 01 x Sel

Page 33

Chapter 2. Programming PELLERIN MILNOR CORPORATION Table 8: Summary of Drain Type Choices Basket Motion Drain Type Help Screen Description

Page 34

Preface PELLERIN MILNOR CORPORATION Milnor provides native displays for several languages. If the native language is not provided by Milnor, the

Page 35

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation 4 Stop with drain—The basket is kept stationary while

Page 36

Chapter 2. Programming PELLERIN MILNOR CORPORATION Table 9: Summary of Choices for Ending a Formula How to End Help Screen Description Baske

Page 37 - PELLERIN MILNOR CORPORATION

Chapter 2. Programming PELLERIN MILNOR CORPORATION Note 5: End Codes 4, 5, 6, and 7 automatically shut off the operator signal two minutes after

Page 38

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation CAUTION 18 : Ensure programming changes are saved—If the

Page 39

Chapter 2. Programming PELLERIN MILNOR CORPORATION codes are discretionary and are so indicated below, most configure codes must match those sho

Page 40

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.4.2. The Configure Decisions Display or Action Explanation LANGUAGE ? 0=ENGLISH

Page 41

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation Select from options 1 through 3 if steam is availabl

Page 42

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation LEVEL 2 HEIGHT ? 8 This value is the depth of the water

Page 43

Chapter 2. Programming PELLERIN MILNOR CORPORATION Table 10: Recommended Water Levels Suggested Level 1 (Low Level) Suggested Level 6 (High L

Page 44

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation The following two configure decisions are available on F_

Page 45 - The Configure Decisions

Table of Contents PELLERIN MILNOR CORPORATION Table of Contents Sections Figures, Tables, and Supplements Preface i. About This Manual (Do

Page 46

Chapter 2. Programming PELLERIN MILNOR CORPORATION Chart 1: Restore Standard Formulas Start A1: Restore standard formulas? NO

Page 47

Chapter 2. Programming PELLERIN MILNOR CORPORATION The remainder of this document details the procedure for restoring the industry standard formul

Page 48

Chapter 2. Programming PELLERIN MILNOR CORPORATION Table 11: Controllers Capable of Transferring Memory Machine Controller Typical Machine M

Page 49

Chapter 2. Programming PELLERIN MILNOR CORPORATION Figure 6: Controls Identification on Serial Memory Storage Device Serial Memory Storage Device

Page 50

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.6.1. Establishing the Required Connections Display or Action Explanation Tu

Page 51

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.6.2. Saving Data from the Machine to the Storage Device or a Second Machine Display or

Page 52

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation CAUTION 27 : Data Corruption Hazard—If the machine cont

Page 53

Chapter 2. Programming PELLERIN MILNOR CORPORATION 2.3.6.3. Restoring Saved Data to the Machine from the Storage Device or Another Machine Dis

Page 54

Chapter 2. Programming PELLERIN MILNOR CORPORATION Display or Action Explanation As soon as the Transmit button on the data storage

Page 55

Chapter 3. Operating PELLERIN MILNOR CORPORATION Chapter 3 Operating BICJHO01 (Published) Book specs- Dates: 20070828 / 20070828 / 2007082

Page 56

Table of Contents PELLERIN MILNOR CORPORATION Sections Figures, Tables, and Supplements 1.4.1.3. Liquid Chemical Tube Connectors 1.4.2.

Page 57

Chapter 3. Operating PELLERIN MILNOR CORPORATION 3.1.2.2. Selecting a Formula Display or Action Explanation RUN FORMULA 00 OK TO POWER

Page 58

Chapter 3. Operating PELLERIN MILNOR CORPORATION Table 12: Coast Times (in seconds) at Program End or Termination Model Door Unlock Delay (DUD

Page 59 - Operating

Chapter 3. Operating PELLERIN MILNOR CORPORATION 3.1.4. The Display During Automatic Operation Display or Action Explanation 23:04 F0

Page 60 - Unloading the Machine

Chapter 3. Operating PELLERIN MILNOR CORPORATION 3.1.5. How to Shorten, Terminate, or Suspend a Running Formula Display or Action Explanation

Page 61

Chapter 3. Operating PELLERIN MILNOR CORPORATION washer extractors employ a feature called cooldown to gradually lower the water temperature and

Page 62 - Chapter 3. Operating

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION Chapter 4 Troubleshooting BICJHT03 (Published) Book specs- Dates: 20070828 / 200708

Page 63 - How Cooldown Works

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION 4.1.1.2. How to Access the Manual Menu Display or Action Explanation RUN FORMUL

Page 64

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION 4.1.3. Viewing Microprocessor Inputs The on/off state of each input to the microprocessor

Page 65 - Troubleshooting

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION Display or Action Explanation ` Accesses the Manual menu. MANUAL MENU 3 TEST

Page 66

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION Table 14: E-P Plus Outputs Output Number Page-Column Description Device Consequen

Page 67

Table of Contents PELLERIN MILNOR CORPORATION Sections Figures, Tables, and Supplements 2.3.4. Configure the Control (Option 2) (Document B

Page 68

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION Figure 7: Processor Board Photograph of Typical Processor Board Legend .

Page 69 - Chapter 4. Troubleshooting

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION Table 15: Interpretation of Test DIP Switch Display Industry Configuration Standard Dis

Page 70 - Figure 7: Processor Board

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION Figure 8: Level Sensor Testing Fixture Fixture Legend . A. graduated

Page 71

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION proportionally according to the pressure in the plastic tube. The instrumentation amplifier

Page 72 - Supplement 5

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION Figure 9: Pressure Transducer Component Identification “Rev. E” Processor Board Legend

Page 73

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION BICJHT01 (Published) Book specs- Dates: 20070828 / 20070828 / 20070828 Lang: ENG01 A

Page 74 - — End of BICJHT03 —

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION 4.2.2. Error Messages during Normal Operation If an error message appears on the bottom

Page 75 - Error Messages at Power Up

Chapter 4. Troubleshooting PELLERIN MILNOR CORPORATION Display or Action Explanation On 48040F7J/F7B models, this error indicates that

Page 76

Chapter 5. Supplemental Information PELLERIN MILNOR CORPORATION Chapter 5 Supplemental Information BICJUF01 (Published) Book specs- Date

Page 77 - Chapter 4. Troubleshooting

Chapter 5. Supplemental Information PELLERIN MILNOR CORPORATION 5.1.4. CPU Processor Board The central processing unit (CPU) processes data rece

Page 78 - Supplemental Information

Table of Contents PELLERIN MILNOR CORPORATION Sections Figures, Tables, and Supplements 4.1.6. Testing Temperature and Level Sensors Figur

Page 79 - Temperature Probe

Chapter 5. Supplemental Information PELLERIN MILNOR CORPORATION 5.1.9. Pressure Sensor The 188 E-P Plus® processor board contains a pressure t

Page 80 - Pressure Sensor

Chapter 5. Supplemental Information PELLERIN MILNOR CORPORATION Figure 11: Rear View of Circuit Board View Legend . 1. DIP switch 2.

Page 81 - Required)

Chapter 5. Supplemental Information PELLERIN MILNOR CORPORATION cabinet-mounted 9-pin DIN type receptacle shown in Figure 12 and may be installe

Page 82 - Pin Identification

Chapter 5. Supplemental Information PELLERIN MILNOR CORPORATION Table 17: External Serial Link Pin Assignments Receptacle Wiring (inside electri

Page 83 - How to Wire the Cables

Chapter 5. Supplemental Information PELLERIN MILNOR CORPORATION Figure 13: Wiring Diagram for Cable to Connect Two or More Machines Receptacle O

Page 84 -

Chapter 5. Supplemental Information PELLERIN MILNOR CORPORATION Figure 14: Wiring Diagram for Cable to Connect a Machine to a Serial Memory Storag

Page 85

Table of Contents PELLERIN MILNOR CORPORATION Sections Figures, Tables, and Supplements 5.3.2.3. Connecting a Machine to a Serial Memory Stor

Comments to this Manuals

ADOLFO RUIZ 25 Mar 2026 | 02:12:21

HOLA BUSCO LOS DIAGRAMAS DEL EQUIPO NUM. DE MODELO:30022V6J AÑO 2000 ESPERANDO RESULTADO FAVORABLE QUEDO DE USTEDES...GRACIAS DE ANTEMANO. Y SI SE REQUIERE CUBRIR ALGUN COSTO FAVOR DE INDICARLO...